全国24小时服务热线:13021103555
Reasons and Preventive Measures of Hardness Insufficiency in Quenching Medium
Cryogenic box, liquid nitrogen cryogenic box, ultra-cryogenic box,
cryogenic equipment, cryogenic furnace, cryogenic treatment equipment,
cryogenic assembly box, cryogenic assembly equipment, high and low
temperature environment box
1. The low quenching temperature is mainly caused by improper process
setting temperature, error of temperature control system, improper
method of loading furnace or entering cooling tank, etc. The process
temperature should be corrected, the temperature control system should
be checked and checked. When loading furnace, the workpiece interval
should be reasonably arranged evenly, dispersed into the tank, and no
accumulation or bundling into the tank for cooling should be prohibited.
2. The quenching temperature is too high, which is caused by improper
process setting temperature or temperature control system error. The
process temperature should be corrected, and the temperature control
system should be checked and checked.
3. Overtempering, which is caused by over-tempering temperature setting,
fault error of temperature control system or when the furnace
temperature is too high, should correct the process temperature, check
and check the temperature control system, not higher than the furnace
temperature loading.
4. The reason for improper cooling is that the pre-cooling time is too
long, the choice of cooling medium is inappropriate, the temperature of
quenching medium increases gradually and the cooling performance
decreases, the stirring is not good or the temperature of outlet tank is
too high. Measures should be taken: quicker outlet and outlet tank;
master the cooling characteristics of quenching medium; oil temperature
60-80 C, water temperature below 30 C; when quenching amount is large
and the cooling medium is heated, cooling quenching medium should be
added or changed. Cooling in other cooling tanks, strengthening the
agitation of coolant, and removing at MS+50 C.
5. Decarbonization is caused by the residual decarbonization layer of
raw materials or quenching heating. The preventive measures are
controlled atmosphere heating, salt bath heating, vacuum furnace and box
furnace using packing protection or anti-oxidation coating, and the
machining allowance is increased by 2-3 mm.